{"product_id":"8-x-40-freshwater-reverse-osmosis-membrane","title":"8\" x 40\" Freshwater Reverse Osmosis Membrane","description":"\u003cp\u003e\u003cstrong\u003eWhen a plant runs on 8\" x 40\" reverse osmosis elements, a membrane change is a planned event, not a guess.\u003c\/strong\u003e Production, permeate quality and operating cost all ride on those elements, so the replacement has to match the vessel, the feed water class and the system design.\u003c\/p\u003e\u003cp\u003eThe Crystal Quest 8\" x 40\" Freshwater Reverse Osmosis Membrane (CQE-RC-040862, the 8040 element size) is a freshwater RO element for systems built around 8\" x 40\" membrane pressure vessels. It is sold as one element, for operators, service companies and installers maintaining larger commercial and industrial RO trains on fresh municipal or well water.\u003c\/p\u003e\u003ch3\u003eAt a glance\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8040 format\u003c\/strong\u003e for 8\" x 40\" membrane pressure vessels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFreshwater class:\u003c\/strong\u003e for fresh municipal and well water; brackish water and seawater desal 8\" x 40\" elements are sold separately\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlanned service life of 2 to 3 years;\u003c\/strong\u003e actual life depends on feed water quality, system configuration and usage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne element per order line,\u003c\/strong\u003e with no pressure vessel, so you buy exactly the count your train needs\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat you are looking at\u003c\/h3\u003e\u003cp\u003eAn 8040 is the large-format spiral-wound element used in bigger RO plants: 8\" in diameter and 40\" long. Leaves of membrane, separated by mesh feed spacers, are rolled around a central permeate tube. Because area grows with diameter, an 8\" element carries far more membrane than a 4\" element of the same length, which is why large systems use them to keep the number of vessels down. Several elements are usually loaded end to end inside one pressure vessel, each sealed against the vessel wall by its brine seal so feed water cannot bypass it.\u003c\/p\u003e\u003ch3\u003eHow an 8040 element works\u003c\/h3\u003e\u003ch4\u003ePressure and cross-flow\u003c\/h4\u003e\u003cp\u003eThe high-pressure pump drives feed water past the membrane surface at a pressure greater than the osmotic pressure of its dissolved salts. Water passes through the membrane into the permeate channels and spirals to the center tube, while dissolved ions stay in the feed stream. The concentrate continues to the next element in the vessel and finally to drain, sweeping the surfaces as it goes.\u003c\/p\u003e\u003ch4\u003eWhy the class matters\u003c\/h4\u003e\u003cp\u003eFreshwater, brackish water and seawater elements are built for very different salt loads and operating pressures. A freshwater element in brackish feed will not reach the permeate quality the system was designed for, and a seawater element in fresh feed wastes pump energy. Match the class your system was designed and projected for.\u003c\/p\u003e\u003ch4\u003eReading performance\u003c\/h4\u003e\u003cp\u003eRejection is feed TDS minus permeate TDS, divided by feed TDS. Track it with feed pressure, differential pressure and permeate flow, corrected for water temperature, because colder water lowers output.\u003c\/p\u003e\n\u003ch3\u003eWhat it reduces\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003ePrimary target:\u003c\/strong\u003e dissolved salts and minerals (TDS) in fresh feed water: the hardness, sodium, chloride and sulfate ions that cause scale, spotting and process problems downstream.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAlso held back:\u003c\/strong\u003e any particle that reaches the membrane is far too large to pass, but particles and colloids foul the surface, so they belong to the pre-filters.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNot designed to handle:\u003c\/strong\u003e oxidizers such as free chlorine, which damage RO membranes; heavy sediment, iron, manganese or organics without pretreatment; or brackish and seawater feeds. Where the feed tends to scale, Crystal Quest \u003ca href=\"https:\/\/crystalquest.com\/products\/membrane-antiscalant\"\u003eMembrane Antiscalant\u003c\/a\u003e is injected into the feed ahead of the cartridge filter to control scale-forming minerals and silica.\u003c\/p\u003e\u003ch3\u003eWhy Crystal Quest\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll three classes in the 8040 size:\u003c\/strong\u003e freshwater, \u003ca href=\"https:\/\/crystalquest.com\/products\/8-x-40-brackish-water-reverse-osmosis-membrane\"\u003ebrackish water\u003c\/a\u003e and \u003ca href=\"https:\/\/crystalquest.com\/products\/8-x-40-seawater-desal-reverse-osmosis-membrane\"\u003eseawater desal\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial RO experience:\u003c\/strong\u003e Crystal Quest designs and supports municipal, commercial and industrial treatment, so we can help you read your log and choose the right element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver 1,000,000 people served since 1994.\u003c\/strong\u003e Crystal Quest builds under ISO 9001 quality management, has made water filtration in the USA for over 30 years and offers lifetime support by phone, email or chat.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhere it fits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRO systems with 8\" x 40\" membrane pressure vessels\u003c\/strong\u003e designed for freshwater feed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNot for Crystal Quest whole house, Mid-Flow or High-Flow RO systems:\u003c\/strong\u003e those use 2.5\" or 4\" elements. See the \u003ca href=\"https:\/\/crystalquest.com\/products\/4-x-40-ro-membrane\"\u003e4\" x 40\" Freshwater Reverse Osmosis Membrane\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eConfirm the element class, size and count against your system's replacement list or design projection before ordering. RO membranes are not returnable under our \u003ca href=\"https:\/\/crystalquest.com\/policies\/refund-policy\"\u003erefund policy\u003c\/a\u003e; \u003ca href=\"https:\/\/crystalquest.com\/pages\/contact-us\"\u003econtact us\u003c\/a\u003e and we will check the match with you.\u003c\/p\u003e\u003ch3\u003eLow energy, standard 8040 format\u003c\/h3\u003e\u003cp\u003eThis is a low-energy freshwater element in the standard 8040 (8\" x 40\") format used in 8\" membrane pressure vessels. Freshwater elements are built for the lower pressures of fresh municipal and well water, so the high-pressure pump does less work than it would with brackish or seawater elements. Several elements usually share one vessel, joined by interconnectors. A shared format name is a good start, not a guarantee: confirm the element class, brine seal and permeate tube ends against your current elements or your system's design projection, or \u003ca href=\"https:\/\/crystalquest.com\/pages\/contact-us\"\u003econtact us\u003c\/a\u003e before ordering.\u003c\/p\u003e\u003ch3\u003eStorage and handling\u003c\/h3\u003e\u003cp\u003eKeep each element in its sealed packaging until you are ready to install it, store it indoors out of direct sunlight, and never let it freeze. Once an element has been installed and wetted, do not let it dry out. If your system will sit idle for a season, \u003ca href=\"https:\/\/crystalquest.com\/products\/membrane-persavtive\"\u003eMembrane Preservative\u003c\/a\u003e is used to protect the elements against damage from bacterial growth.\u003c\/p\u003e\u003ch3\u003eCommon questions\u003c\/h3\u003e\u003cdiv class=\"cq-product-faq\"\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eWhich systems use an 8\" x 40\" element?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eSystems built around 8\" x 40\" membrane pressure vessels. Check your system's replacement list or contact Crystal Quest to confirm before ordering.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eIs this an 8040 RO membrane?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eYes, 8\" x 40\" is the 8040 format. Format alone does not guarantee a match, so confirm the class and your system's design before you order.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eFreshwater, brackish or seawater?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eCrystal Quest sells 8\" x 40\" elements in freshwater, brackish water and seawater desal classes. Choose the class your system and feed water are designed for.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eHow long does the element last?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eAbout 2 to 3 years. Actual life depends on feed water quality, system configuration and usage.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eShould I replace every element in the vessel at once?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eUsually yes. Replacing the full set keeps the elements in a vessel sharing the load evenly. If only part of a train is underperforming, call us and we will help you read your log first.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eDoes it include a pressure vessel?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eNo. This listing is one membrane element.\u003c\/p\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n###\n\u003ch3\u003eElement specifications\u003c\/h3\u003e\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\"\u003eMembrane type\u003c\/td\u003e\n\u003ctd valign=\"middle\"\u003eThin-film composite (TFC) reverse osmosis element\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\"\u003eApplication\u003c\/td\u003e\n\u003ctd valign=\"middle\"\u003eFreshwater (low energy), for feed water up to about 2,000 ppm TDS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\"\u003eElement size\u003c\/td\u003e\n\u003ctd valign=\"middle\"\u003e8\" x 40\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\"\u003ePart number\u003c\/td\u003e\n\u003ctd valign=\"middle\"\u003eCQE-RC-040862\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\"\u003eService life\u003c\/td\u003e\n\u003ctd valign=\"middle\"\u003e2 to 3 years*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eElement operating limits\u003c\/strong\u003e\u003c\/p\u003e\u003ctable width=\"100%\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated production\u003c\/td\u003e\n\u003ctd\u003e12,500 GPD at 150 psi, 550 ppm feed, 77°F (25°C), 15% recovery; actual output drops with colder or saltier water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal salt rejection\u003c\/td\u003e\n\u003ctd\u003e99.5% (99% minimum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest conditions\u003c\/td\u003e\n\u003ctd\u003e550 ppm feed, 150 psi, 77°F (25°C), 15% recovery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating pressure\u003c\/td\u003e\n\u003ctd\u003eRated maximum: 600 psi; suggested operating range: 100 to 150 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum temperature\u003c\/td\u003e\n\u003ctd\u003e113°F (45°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH range\u003c\/td\u003e\n\u003ctd\u003eRated 2 to 11; suggested 5 to 11 for continuous operation; cleaning 2 to 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree chlorine tolerance\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm maximum. Remove chlorine and chloramine before the membrane with carbon pre-filtration (Crystal Quest whole house RO systems include this).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilt density index\u003c\/td\u003e\n\u003ctd\u003eLess than 5 SDI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum pressure drop\u003c\/td\u003e\n\u003ctd\u003e15 psi per element\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure vessel\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e*Service life is an estimate. Actual life depends on feed water quality, system configuration and usage. Rejection, production, test conditions and operating limits are from the element data sheets. The 600 psi rating is the element's structural limit. Low energy elements are designed to make their rated flow at about 150 psi. Never exceed the lower of these limits and your pressure vessel's or system's own ratings.\u003c\/p\u003e\u003cp\u003e\u003cimg width=\"1024\" height=\"571\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1286\/9985\/files\/RO_Membrane_Illustration_1024x1024.png?v=1615830985\" alt=\"Illustration of a Crystal Quest freshwater reverse osmosis membrane element\"\u003e\u003c\/p\u003e\n","brand":"Crystal Quest Water Filters","offers":[{"title":"Single","offer_id":68431380480304,"sku":"CQE-RC-040862","price":598.25,"currency_code":"USD","in_stock":true},{"title":"Pack of 2","offer_id":68431380513072,"sku":"CQE-RC-040862-2PK","price":1196.5,"currency_code":"USD","in_stock":true},{"title":"Pack of 4","offer_id":68431380545840,"sku":"CQE-RC-040862-4PK","price":2393.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1001\/2868\/6384\/files\/single-8-x-40-freshwater-reverse-osmosis-membrane-crystal-quest-water-filter-cartridges-1263586059.webp?v=1794517826","url":"https:\/\/estateoutdoorspaces.com\/products\/8-x-40-freshwater-reverse-osmosis-membrane","provider":"Estate Outdoor Spaces","version":"1.0","type":"link"}